HP Z600 and Z800 Workstations - Sliding rack-mount kit installation
Installing on round hole and square hole HP racks
These instructions apply to racks such as standard HP racks.
NOTE: To determine the appropriate alignment for a workstation that requires a 4U space (HP Z600
Workstations) or a 5U space (HP Z800 Workstations), see the two
Figure 12 Mounting reference
guides on page 11.
1. Engage the three pins on the rear slide mounting bracket in the holes in the rear rack column, and
then slide forward to lock in place (1).
2. Engage the three pins on the front slide mounting bracket in the holes in the front rack column, and
then slide backward to lock in place (2).
NOTE: The slide telescopes to accomplish this task.
Repeat this procedure for the second slide.
3. If the slide must be repositioned, release the rear bracket (3).
4. If the slide must be repositioned, release the front bracket (4).
Figure 6 Installing on round and square hole HP racks
5. Continue with Step 4—Mounting into a rack on page 10.
ENWW Step 3—Installing rails to the rack 7