Intel vPro Processor Technology Setup and Configuration for the HP Z1, Z210, Z420, Z620 and Z820 Workstations

20
6. Review system information and make any necessary changes.
Note:
The MEBx password can be changed for the remote
system in the WebGUI.
Changing the password in the WebGUI or a remote
console will result in two passwords. The new password,
known as the “remote” MEBx password, will only work
remotely with the WebGUI or remote console. The local
MEBx password used to access the MEBx locally will not
be changed! The user will have to keep track of both local
and remote MEBx passwords to be able to access the
system MEBx locally and remotely. When the MEBx
password is initially set in AMT Setup, it serves as both the
local and remote password. They are in sync. If the remote
password is changed, then the passwords are out of sync.
The remote MEBx password must also follow the criteria
defined in the Password Guideline section for a strong
password.
7. Exit.