Owner's manual
• Thermal Status—Displays the temperature status of the drive system. The following values are
possible:
◦ OK—The temperature is within normal operating range.
◦ Degraded—The temperature is outside of normal operating range. Check to make sure
the cover is on the storage system.
◦ Failed—The temperature is outside of normal operating range, and could permanently
damage the system. Ensure that the fans are spinning, and check the room temperature.
◦ Unknown—The Storage Agents do not recognize the thermal status. You may need to
upgrade your software.
◦ No Temperature Monitoring—This storage system does not support temperature monitoring.
• Side Panel—Displays the status of the side panel of the drive enclosure, or box. The following
values are possible:
◦ In Place—The side panel is closed.
◦ Removed—The side panel is not in place or not completely closed.
◦ Unknown—The Storage Agents do not recognize the side panel status. You may need
to upgrade your software.
◦ No Panel Detection—This storage system does not support side panel detection.
• Duplex Option—Displays the duplex option installed in this storage system. The following
values are possible:
◦ Duplex Top—This storage system is the top part of a duplexed unit.
◦ Duplex Bottom—This storage system is the bottom part of a duplexed unit.
◦ None—A duplex option is not installed.
• Power Supply Status—Displays the status of the redundant power supply. The following values
are possible:
◦ OK—All component power supplies that make up the redundant power supply are in
normal working order.
◦ Degraded—One of the component power supplies that make up the redundant power
supply has failed. The drive system (either a drive subsystem or a power supply for the
main unit) continues to operate; however, if the remaining power supply should fail, the
drive system loses power and data loss could occur. To correct this situation, schedule a
time to bring the device down and replace the failed power supply.
60 Agent information