Specifications
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 135
Troubleshooting
Data2 Data3
80 03 ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_DOWN (“p 0”)
81 03 ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_UP (“p 1”)
80 01 ipmi req from via BT for CHASSIS_CONTROL_POWER_DOWN
83 03 ipmi/RS req from the CLI thd for CHASSIS_CONTROL_HARD_RESET
00 FA CHASSIS_CONTROL_POWER_DOWN req from the ACPI sensor (S5)
00 D9 CHASSIS_CONTROL_POWER_DOWN req from CPU0 temp sensor
01 0E CHASSIS_CONTROL_POWER_UP req from WakeOnLan sensor
Events Without Sensors
The BMC logs these events with a “sensor number” of 0; there is no matching SDR entry.
Triplet Event data2 data3 Notes
10:70:64 SEL almost full 1F %full The BMC logs this when the SEL is
75% full
12:70 : 0 4 B MC e n ter i n g firmwa re
update mode
12:70:05 SFW flash lnlock System firmware update in
progress
12:70:06 Front panel lock Disables all power and reset
requests from ipmi or sensors
12:F0:06 Front panel unlock
12:70:07 Firmware update app:
starting component update
12:F0:07 Firmware update app:
ending component update
12:70:80 BMC entering special
mode
Mode – Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
12:70 : A 1 BMC fi r mwa re i n i t i a l iz i n g M a jor F W
rev
Minor
FW rev
1D:70:00 BMC cold reset
1D:70:01 BMC warm reset
1D:70:02 BMC cold reset after SDRR
update