Specifications

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 71
Removing and Replacing Components
3.
Align the Front Bezel
Removing and Replacing Hot-Swappable and
Hot-Pluggable Devices
The rx2600 and zx6000 have hard disk drives that are hot-pluggable and power supplies and fans
that are hot-swappable. This section explains how to swap the following devices while the server
is running:
System fans
Power supplies
Hard drives
System Fans
There are four system fans that keep the server cool when it is running. The system fans are
hot-swappable. This enables you to replace a fan while the server is running.
CAUTION: When the server is running, you must replace the top cover within four minutes to prevent
components from overheating.
Removing a System Fan
To remove a system fan, follow these steps
1. Remove the server covers.
2. Remove the fan.
a. Grasp the appropriate fan and lift it out of the fan socket to remove it:
fan 1A, 1B, 2, or 3 from a rack-mounted server, or
fan 3 from a pedestal-mount server
1
2