Instruction Manual

RESTART OA
Command:
RESTART OA [<bay number>]
Description:
Resets the Onboard Administrator module specified by <bay number>. If no bay number is
given, then the Onboard Administrator the user is logged in to is restarted.
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
None
SET DISPLAY EVENTS
Command:
SET DISPLAY EVENTS {ON | OFF}
Description:
Turns the displaying of events that are triggered by status changes in the system on or
off.
This command is specific to the CLI session, and must be issued for every CLI session to
display events in that session.
Access level/Bay level:
All
Restrictions:
Only for bays for which you have privileges
SET ENCLOSURE ASSET
Command:
SET ENCLOSURE ASSET [TAG] "<asset tag>"
Description:
Sets the enclosure asset tag
The default enclosure asset tag is blank
Access level/Bay level:
OA Administrator, OA Operator
Restrictions:
The <asset tag> must be 0 to 32 characters long and includes all alphanumeric, underscore
(_), and dash (-) characters.
RESTART OA 73