Instruction Manual
SET ENCLOSURE SERIAL_NUMBER
• Command:
SET ENCLOSURE SERIAL_NUMBER "<serial number>"
• Description:
Sets the enclosure serial number.
• Access level/Bay level:
OA Administrator
• Restrictions:
Must be 10 characters in length and includes all alphanumeric, underscore (_), and dash (-)
characters.
SET ENCLOSURE UID
• Command:
SET ENCLOSURE UID {ON | OFF}
• Description:
Turns the UID LED of the enclosure on or off.
• Access level/Bay level:
OA Administrator, OA Operator
• Restrictions:
None
SET IOX UID
• Command:
SET IOX UID { ALL | <iox number> [{-|,}] <iox number>]} {ON | OFF}
• Description:
Turns the UID LED of the specified IOX enclosures on or off.
• Access level/Bay level:
OA Administrator, OA Operator, OA user
• Restrictions:
You must be logged on to the monarch OA to perform this command.
SET LLF INTERVAL
• Command:
SET LLF INTERVAL <seconds>
• Description:
Set the Link Loss Failure Interval
• Access level/Bay level:
Operator, Administrator
• Restrictions:
Must have OA permission to perform this command.
SET ENCLOSURE SERIAL_NUMBER 75