HP Point of Sale (POS) Peripherals Configuration Guide
Page 87 of 522
The single station printer with serial interface requires two cables: power (hosiden) and
serial data cable.
The following is the powered (hosiden) cable for the single station printer with
serial interface:
The serial data cable is standard null modem cable and the following is the pin out
of the cable:
Pin #
Pin #
1
NC (no
connect)
2
3
3
2
4
6
5
5
6
4
7
8
8
7
9
NC (no
connect)
Shield
Frame
Ground