Programming Reference Guide
1D Code Selection Enter/Exit Programming Mode
Programming Reference Guide
153
MSI Set Length 2
This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is
the maximum label length if in Variable Length Mode, or the second fixed length if in
Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift
characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this
length (only one fixed length).
Table 22 provides examples for setting Length 2. See page 219 for detailed instructions on
setting this feature.
Table 22. MSI Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Le
ngth)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT MSI LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select MSI Length 2 Setting
Make a mistake? Scan the CANCEL barcode to
abort and not save the entry string. You can
then start again at the beginning.
CANCEL
$CMSL2
~
DEFAULT
50 = Length 2 is 50 Characters