HP SureStore AutoBackup Administrator's Guide - Not Orderable

Baseboard temperature
Crossed lower critical
Web:
YES Critical
LCD: YES
Also display
temperature icon
Status Light: Flashing
YELLOW
Baseboard temperature Crossed
lower noncritical
Please click on the URL below to
get details
Help configuring thresholds for
Baseboard Temperature
If temperature falls below
0C, then system performs
an automatic shutdown!
Baseboard temperature
Back to Normal
Web:
YES Warning
LCD: YES
Status Light:
GREEN
Baseboard temperature Back to
Normal
Please click on the URL below to
get details
Help configuring thresholds for
Baseboard Temperature
Automatically cleared after
5 seconds
+12 volts
Crossed upper
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+12 volts Crossed upper
noncritical
Please click on the URL below to
get details
Help configuring thresholds for
+12 volts
User-initiated via detailed
message page, or
Automatically cleared
when power supply
auto-adjusts to correct
problem
+12 volts
Crossed upper critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+12 volts Crossed upper critical
Please click on the URL below to
get details
Help configuring thresholds for
+12 volts
If +12V voltage rises
above 13.44V, then system
performs an automatic
shutdown!
+12 volts
Crossed lower
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+12 volts Crossed lower
noncritical
Please click on the URL below to
get details
Help configuring thresholds for
+12 volts
User-initiated via detailed
message page, or
Automatically cleared
when power supply
auto-adjusts to correct
problem
Troubleshooting, Alert Messages