Datasheet
4
HP ProCurve Switch 5300xl Series
Specifications
HP ProCurve Switch 5308xl (J4819A) HP ProCurve Switch 5372xl (J4848B)
Included accessories
3 HP ProCurve Switch xl 24-Port 10/100-TX Module (J4820B)
Ports
8 open module slots
Supports a maximum of 192 auto-sensing 10/100 ports or 128 auto-sensing
10/100/1000 ports
5 open module slots
72 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type
100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
Supports a maximum of 192 auto-sensing 10/100 ports or 128 auto-sensing
10/100/1000 ports
Power supplies
1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
1 power-supply slots
includes: 1 x J4839AHP ProCurve Switch gl/xl/vl Redundant Power Supply
Physical characteristics
Dimensions
15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height) 15.3(d) x 17.4(w) x 8.75(h) in. (38.86 x 44.2 x 22.23 cm) (5U height)
Weight
26.65 lb. (12.0 kg), Fully loaded 31.05 lb. (14.08 kg), Fully loaded
Memory and processor
Fabric
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM; packet buffer
size: 36 MB
Motorola PowerPC @ 200 MHz, 12 MB flash, 32 MB SDRAM
Module
ARM7 @ 66 MHz, 128 KB flash, 128 KB SRAM, 18 MB RDRAM; packet buffer
size: 36 MB
Mounting
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
Performance
Latency
< 6 µs (FIFO) < 6 µs (FIFO)
Throughput
up to 48 million pps up to 48 million pps
Switch fabric speed
76.8 Gbps 76.8 Gbps
Routing table size
10,000 entries 10,000 entries
Environment
Operating temperature
32ºF to 104ºF (0ºC to 40ºC) 32ºF to 104ºF (0ºC to 40ºC)
Operating relative humidity
15% to 95% @ 104ºF (40ºC), non-condensing 15% to 95% @ 104ºF (40ºC), non-condensing
Non-operating/Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC) -40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing 15% to 95% @ 149ºF (65ºC), non-condensing
Altitude
up to 15,000 ft. (4.6 km) up to 15,000 ft. (4.6 km)
Electrical characteristics
Maximum heat dissipation
2152 BTU/hr (2270 kJ/hr) 2152 BTU/hr (2270 kJ/hr)
Voltage
100-127 / 200-240 VAC 100-127 / 200-240 VAC
Current
8.2 / 3.8 A 8.2 / 3.8 A
Power consumption
630 W 630 W
Frequency
50 / 60 Hz 50 / 60 Hz
Notes
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules
populated.
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules
populated.
Safety
cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd
edition
cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd
edition
Emissions
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24 EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3 V/m IEC 61000-4-3; 3 V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line) IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC IEC 61000-4-5; 1 kV/2 kV AC
Conducted
IEC 61000-4-6; 3 V IEC 61000-4-6; 3 V
Power frequency magnetic field
IEC 61000-4-8; 1 A/m, 50 or 60 Hz IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics
EN 61000-3-2, IEC 61000-3-2 EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3 EN 61000-3-3, IEC 61000-3-3
Management
HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line
interface; Web browser; configuration menu; out-of-band management (serial
RS-232C)
HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line
interface; Web browser; configuration menu; out-of-band management (serial