Datasheet

ProCurve Switch 4100gl Series
ProCurve Switch 4104gl (J4887A) ProCurve Switch 4140gl (J8151A) ProCurve Switch 4148gl (J4888A)
What’s included N/A 2 ProCurve Switch gl 20-Port 10/100/1000 2 ProCurve Switch gl 24-Port 10/100-TX
Module (J4908A) Module (J4862B)
Ports 4 open module slots 2 open module slots 2 open module slots
1 RS-232C DB-9 console port 40 10/100/1000 ports and 4 mini-GBIC slots 48 10/100 ports (2 x J4862B)
1 RS-232C DB-9 console port 1 RS-232C DB-9 console port
Maximum ports Supports a maximum of 96 10/100 por ts or Supports a maximum of 48 10/100 por ts or Supports a maximum of 96 10/100 ports or
80 Gigabit ports plus 8 mini-GBICs, or 80 Gigabit ports plus 8 mini-GBICs, or 40 Gigabit ports plus 4 mini-GBICs, or
24 mini-GBICs, or a combination 16 mini-GBICs, or a combination 12 mini-GBICs, or a combination
Physical characteristics
Dimensions (D x W x H) 38.86 x 44.2 x 13.34 cm 38.86 x 44.2 x 13.34 cm 38.86 x 44.2 x 13.34 cm
(15.3 x 17.4 x 5.25 in.) (3U height) (15.3 x 17.4 x 5.25 in.) (3U height) (15.3 x 17.4 x 5.25 in.) (3U height)
Weight (fully loaded) 6.7 kg (14.75 lb.) 10.4 kg (22.9 lb.) 7.18 kg (15.84 lb.)
Memory and processor
Fabric processor type and speed Motorola PowerPC @ 200 MHz, Motorola PowerPC @ 200 MHz, Motorola PowerPC @ 200 MHz,
8 MB flash, 32 MB SDRAM 8 MB flash, 32 MB SDRAM 8 MB flash, 32 MB SDRAM
Module processor type and speed IDT MIPS32 @ 125 MHz IDT MIPS32 @ 125 MHz IDT MIPS32 @ 125 MHz
Flash 512 KB 512 KB 512 KB
SRAM N/A N/A N/A
Packet buffer size 512 KB 512 KB 512 KB
SDRAM 8 MB 8 MB 8 MB
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included) horizontal surface mounting only
Performance
Latency <10.2 µs (FIFO 64-byte packets) <10.2 µs (FIFO 64-byte packets) <10.2 µs (FIFO 64-byte packets)
Throughput Up to 35.7 million pps Up to 35.7 million pps Up to 35.7 million pps
Switch fabric speed 18.3 Gbps 18.3 Gbps 18.3 Gbps
Routing table size 8,000 entries 8,000 entries 8,000 entries
Environment
Operating temperature 0°C to 55°C (32°F to 131°F) 0°C to 55°C (32°F to 131°F) 0°C to 55°C (32°F to 131°F)
Operating relative humidity 15% to 95% @ 40°C (104°F), non-condensing 15% to 95% @ 40°C (104°F), non-condensing 15% to 95% @ 40°C (104°F), non-condensing
Non-operating/Storage temperature –40°C to 70°C (–40°F to 158°F) –40°C to 70°C (–40°F to 158°F) –40°C to 70°C (–40°F to 158°F)
Non-operating/Storage relative humidity 15% to 95% @ 65°C (149°F), non-condensing 15% to 95% @ 65°C (149°F), non-condensing 15% to 95% @ 65°C (149°F), non-condensing
Altitude Up to 4.6 km (15,091 ft.) Up to 4.6 km (15,091 ft.) Up to 4.6 km (15,091 ft.)
Electrical characteristics
Maximum BTUs 2,152 BTU/hr 2,152 BTU/hr 2,152 BTU/hr
Voltage 100–127 VAC/200–240 VAC 100–127 VAC/200–240 VAC 100–127 VAC/200–240 VAC
Current 8.2 A/3.8 A 8.2 A/3.8 A 8.2 A/3.8 A
Power consumption 630 W 630 W 630 W
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
Safety cUL (CSA 950); EN 60950/IEC 60950;NOM-019-SCFI-1994; UL 1950 3rd edition
Emissions FCC Class A; EN55022/CISPR-22 Class A; VCCI Class A
Immunity
EN EN55024, CISPR-24 EN55024, CISPR-24 EN55024, CISPR-24
ESD IEC 61000-4-2; 4kV CD, 8 kV AD IEC 61000-4-2; 4kV CD, 8 kV AD IEC 61000-4-2; 4kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3V/m IEC 61000-4-3; 3V/m IEC 61000-4-3; 3V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), IEC 61000-4-4; 1.0 kV (power line), IEC 61000-4-4; 1.0 kV (power
0.5 kV (signal line) 0.5 kV (signal line) line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC IEC 61000-4-5; 1 kV/2 kV AC IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3V IEC 61000-4-6; 3V IEC 61000-4-6; 3V
Power frequency magnetic field IEC 61000-4-8; 1A/m, 50 or 60 Hz IEC 61000-4-8; 1A/m, 50 or 60 Hz IEC 61000-4-8; 1A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; IEC 61000-4-11; >95% reduction, 0.5 period; IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods 30% reduction, 25 periods 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2 EN 61000-3-2, IEC 61000-3-2 EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3 EN 61000-3-3, IEC 61000-3-3 EN 61000-3-3, IEC 61000-3-3
Management ProCurve Manager (included); ProCurve Manager Plus; command-line inter face; Web browser; configuration menu; out-of-band management
(serial RS-232C)
Standards and protocols RFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 Simple
Network Time Protocol; IEEE 802.3x Flow Control; DHCP Relay; RFC 2236 IGMP v1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence
Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol; RFC 1492 TACACS+; RFC 2138 RADIUS; RFC 2866 RADIUS accounting; SSHv1/SSHv2
Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; IEEE 802.1Q VLAN tagging; IEEE 802.1Q GVRP; IEEE 802.1p Priority;
SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB;
RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm), and 9 (events);
RFC 2021 RMON probe configuration (RMON v2); RFC 2668 IEEE 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 IEEE 802.1p and IEEE 802.1Q Bridge