Datasheet

QuickSpecs
HP 2530 Switch Series
Technical Specifications
c04111414 - DA 14447 Worldwide Version 7 August 18, 2014
Page 28
HP 2530-8-PoE+ Switch
(J9780A)
I/O ports and slots
8 RJ-45 autosensing 10/100 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE
802.3u Type 100BASE-TX, IEEE 802.3at PoE+); Media Type: Auto-MDIX;
Duplex: half or full
2 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-
Tx; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or as a SFP slot (for use
with SFP transceivers) ports
Additional ports and
slots
1 dual-personality (RJ-45 or USB micro-B) serial console port
Physical characteristics
Dimensions
10(w) x 6.28(d) x 1.75(h) in (25.4 x 15.95 x 4.45
cm) (1U height)
Weight
2.0 lb (0.91 kg)
Memory and processor
Processor
ARM9E @ 800 MHz, 128 MB flash, 256 MB DDR3
DIMM; packet buffer size: 1.5 MB dynamically
allocated
Mounting and enclosure
Mounts in an EIA-standard 19-inch telco rack or equipment cabinet (rack-
mounting kit available); horizontal surface mounting; wall mounting
Performance
IPv6 Ready Certified
100 Mb Latency
< 1.3 µs (LIFO 64-byte packets)
1000 Mb Latency
< 2.3µs (LIFO 64-byte packets)
Throughput
4.1 Mpps (64-byte packets)
Switching capacity
5.6 Gbps
MAC address table size
16000 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C)
Operating relative
humidity
15% to 95% @ 104°F (40°C), noncondensing
Non-operating/
Storage temperature
-40°F to 158°F (-40°C to 70°C)
Non-operating/Storage
relative humidity
15% to 90% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft (3 km)
Acoustic
Power: 0 dB, Pressure: 0 dB
Electrical characteristics
Frequency
50/60 Hz
Maximum heat
dissipation
29 BTU/hr (30.6 kJ/hr), (switch only: 29 BTU/hr;
combined switch + max. PoE devices: 262
TU/hr)
AC voltage
100-127/200-240 VAC
Current
1.4 A
Maximum power rating
76.7 W
Idle power
5.8 W
PoE power
67 W
Notes
Idle power is the actual power consumption of
the device with no ports connected.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if
equipped), 100% traffic, all ports plugged in,