The single station printer with serial interface requires two cables: power (hosiden) and 
serial data cable.  
The following is the powered (hosiden) cable for the single station printer with 
serial interface: 
The serial data cable is standard null modem cable and the following is the pin out 
of the cable: 
Pin # 
Pin # 
1 
NC (no 
connect) 
2 
3 
3 
2 
4 
6 
5 
5 
6 
4 
7 
8 
8 
7 
9 
NC (no 
connect) 
Shield 
Frame 
Ground 