Datasheet

8
HP 3100 EI Switch Series
Specifications (continued)
HP 3100-8 V2 EI Switch (JD318B) HP 3100-16 V2 EI Switch (JD319B) HP 3100-24 V2 EI Switch (JD320B)
Ports
8 autosensing 10/100 ports (IEEE 802.3 Type 10BASE-T,
IEEE 802.3u Type 100BASE-TX); Duplex: half or full
1 dual-personality port; auto-sensing
10/100/1000BASE-T or SFP
1 RJ-45 serial console port
16 autosensing 10/100 ports (IEEE 802.3 Type
10BASE-T, IEEE 802.3u Type 100BASE-TX); Duplex: half
or full
2 dual-personality ports; auto-sensing
10/100/1000BASE-T or SFP
1 RJ-45 serial console port
24 autosensing 10/100 ports (IEEE 802.3 Type
10BASE-T, IEEE 802.3u Type 100BASE-TX); Duplex: half
or full
2 dual-personality ports; auto-sensing
10/100/1000BASE-T or SFP
1 RJ-45 serial console port
Physical characteristics
9.06(w) x 6.3(d) x 1.72(h) in (23.01 x 16 x 4.37 cm) (1U
height)
14.17(w) x 6.3(d) x 1.72(h) in (35.99 x 16 x 4.37 cm) (1U
height)
17.32(w) x 6.3(d) x 1.72(h) in (43.99 x 16 x 4.37 cm) (1U
height)
Weight
3.97 lb (1.8 kg) 5.51 lb (2.5 kg) 7.72 lb (3.5 kg)
Memory and processor
128 MB SDRAM, 16 MB flash; packet buffer size: 384 KB 128 MB SDRAM, 16 MB flash; packet buffer size: 384 KB 128 MB SDRAM, 16 MB flash; packet buffer size: 384 KB
Mounting
Requires angle mounting set if rack mounted (not
included)
Requires angle mounting set if rack mounted (not
included)
Mounts in an EIA-standard 19 in. telco rack or equipment
cabinet (hardware included)
Performance
100 Mb Latency
< 6 µs (64-byte packets) < 6 µs (64-byte packets)
1000 Mb Latency
< 5 µs (64-byte packets) < 5 µs (64-byte packets) < 6 µs (64-byte packets)
10 Gbps Latency
< 5 µs (64-byte packets)
Throughput
up to 2.6 million pps up to 5.3 million pps up to 6.5 million pps
Routing/Switching capacity
3.6 Gbps 7.2 Gbps 8.8 Gbps
Routing table size
16 entries 16 entries 16 entries
MAC address table size
8192 entries 8192 entries 8192 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C) 32°F to 113°F (0°C to 45°C) 32°F to 113°F (0°C to 45°C)
Operating relative humidity
10% to 90%, noncondensing 10% to 90%, noncondensing 10% to 90%, noncondensing
Nonoperating/Storage temperature
-40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage relative humidity
5% to 95%, noncondensing 5% to 95%, noncondensing 5% to 95%, noncondensing
Acoustic
N/A (fanless) N/A (fanless) N/A (fanless)
Electrical characteristics
Maximum heat dissipation
31 BTU/hr 41 BTU/hr 44 BTU/hr
Voltage
100-240 VAC 100-240 VAC 100-240 VAC
Maximum power rating
9 W 12 W 13 W
Frequency
50/60 Hz 50/60 Hz 50/60 Hz
Notes
Maximum power rating and maximum heat dissipation
are the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged
in, and all modules populated.
Maximum power rating and maximum heat dissipation
are the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged
in, and all modules populated.
Maximum power rating and maximum heat dissipation
are the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports plugged
in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part
1; EN 60825-2 Safety of Laser Products-Part 2; IEC
60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR;
GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM;
ROHS Compliance
UL 60950-1; EN 60825-1 Safety of Laser Products-Part
1; EN 60825-2 Safety of Laser Products-Part 2; IEC
60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR;
GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM;
ROHS Compliance
UL 60950; NOM-019-SCFI Mexico; EN 60950: 2000, ZB
and ZC Deviations; IEC 60950: 1999, Corr Feb 2000, all
national deviations; AS/NZS 60950: 2000 Australia,
Russian GOST Safety Approval
Emissions
FCC part 15 Class A; VCCI Class A; EN 55022 Class A;
CISPR 22 Class A; ICES-003 Class A; ANSI C63.4 2003;
ETSI EN 300 386 V1.3.3; AS/NZS CISPR22 Class A; EN
61000-3-2; EN 61000-3-3; EN 61000-4-2; EN
61000-4-3; EN 61000-4-4; EN 61000-4-5; EN
61000-4-6; EN 61000-4-11; EN 61000-3-2:2006; EN
61000-3-3:1995 +A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15) Class A
FCC part 15 Class A; VCCI Class A; EN 55022 Class A;
CISPR 22 Class A; ICES-003 Class A; ANSI C63.4 2003;
ETSI EN 300 386 V1.3.3; AS/NZS CISPR22 Class A; EN
61000-3-2; EN 61000-3-3; EN 61000-4-2; EN
61000-4-3; EN 61000-4-4; EN 61000-4-5; EN
61000-4-6; EN 61000-4-11; EN 61000-3-2:2006; EN
61000-3-3:1995 +A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15) Class A
FCC part 15 Class A; VCCI Class A; EN 55022 Class A;
CISPR 22 Class A; ICES-003 Class A; ANSI C63.4 2003;
ETSI EN 300 386 V1.3.3; AS/NZS CISPR22 Class A; EN
61000-3-2; EN 61000-3-3; EN 61000-4-2; EN
61000-4-3; EN 61000-4-4; EN 61000-4-5; EN
61000-4-6; EN 61000-4-11; EN 61000-3-2:2006; EN
61000-3-3:1995 +A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15) Class A
Management
IMC - Intelligent Management Center; command-line
interface; Web browser; SNMP Manager
IMC - Intelligent Management Center; command-line
interface; Web browser; SNMP Manager
IMC - Intelligent Management Center; command-line
interface; Web browser; SNMP Manager
Services
Refer to the HP website at
www.hp.com/networking/services for details on the
service-level descriptions and product numbers. For
details about services and response times in your area,
please contact your local HP sales office.
Refer to the HP website at
www.hp.com/networking/services for details on the
service-level descriptions and product numbers. For
details about services and response times in your area,
please contact your local HP sales office.
Refer to the HP website at
www.hp.com/networking/services for details on the
service-level descriptions and product numbers. For
details about services and response times in your area,
please contact your local HP sales office.