Datasheet

13
Datasheet|HPMSR50RouterSeries
HP MSR50-40 DC Router (JF285A) HP MSR50-60 DC Router (JF640A)
I/O ports and slots 4FICslots 6FICslots
Physical characteristics
Dimensions
Weight
17.17(w)x16.69(d)x5.16(h)in(43.6x42.4x13.1cm)
(3Uheight)
39.68lb(18kg)
17.17(w)x16.69(d)x6.89(h)in(43.6x42.4x17.5cm)
(4Uheight)
44.09lb(20kg)
Memory and processor RISC@1700MHz,1GBDDRSDRAM,256MBcompact
ash
RISC@833MHz,512MBDDRSDRAM,256MBcompact
ash
RISC@1700MHz,1GBDDRSDRAM,256MBcompact
ash
RISC@833MHz,512MBDDRSDRAM,256MBcompact
ash
Mounting and enclosure MountsinanEIA-standard19in.telcorack MountsinanEIA-standard19in.telcorack
Performance
Throughput
Routing/Switchingcapacity
Routingtablesize
upto1280Kpps(64-bytepackets)
3Gbps
100000entries(IPv4),100000entries(IPv6)
upto1280Kpps(64-bytepackets)
3Gbps
100000entries(IPv4),100000entries(IPv6)
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
32°Fto104°F(Cto40°C)
5%to90%,noncondensing
-40°Fto15F(-40°Cto70°C)
5%to90%,noncondensing
32°Fto104°F(Cto40°C)
5%to90%,noncondensing
-40°Fto15F(-40°Cto70°C)
5%to90%,noncondensing
Electrical characteristics
Maximumheatdissipation
Maximumpowerrating
PoEpower
1194BTU/hr(1259.67kJ/hr)
350W
500W
Note
Maximumpowerratingandmaximumheatdissipation
aretheworst-casetheoreticalmaximumnumbers
providedforplanningtheinfrastructurewithfullyloaded
PoE(ifequipped),100%traic,allportspluggedin,and
allmodulespopulated.
PoEpoweristhepowersuppliedbytheinternalpower
supply.Itisdependentonthetypeandquantityofpower
suppliesandmaybesupplementedwiththeuseofan
externalpowersupply(EPS).
1194BTU/hr(1259.67kJ/hr)
350W
500W
Maximumpowerratingandmaximumheatdissipation
aretheworst-casetheoreticalmaximumnumbers
providedforplanningtheinfrastructurewithfullyloaded
PoE(ifequipped),100%traic,allportspluggedin,and
allmodulespopulated.
PoEPoweristhepowersuppliedbytheinternalpower
supply,itisdependentonthetypeandquantityofpower
suppliesandmaybesupplementedwiththeuseofa
ExternalPowerSupply(EPS).
Safety UL60950-1;AS/NZS60950;EN60825-1SafetyofLaser
Products-Part1;EN60825-2SafetyofLaserProducts-
Part2;IEC60950-1;EN60950-1;CAN/CSA-C22.2No.
60950-1-03;FDA21CFRSubchapterJ
UL60950-1;AS/NZS60950;EN60825-1SafetyofLaser
Products-Part1;EN60825-2SafetyofLaserProducts-
Part2;IEC60950-1;EN60950-1;CAN/CSA-C22.2No.
60950-1-03;FDA21CFRSubchapterJ
HP MSR50 Series
Specications (continued)