3 Pull the duplexing-pendulum assembly toward the laser/scanner until the upper gear-drive shaft
clears the hole in the chassis, and then remove the assembly.
CAUTION The gears in this assembly are not captive and can easily slide off of the
shafts. Handle the assembly carefully and place it gear-side-up on your workstation to
prevent the gears from sliding off of the shafts.
Figure 6-42 Duplexing-pendulum assembly (2 of 2)
218 6 Removing and replacing parts