User Guide
Recommended action
1. Turn the product off and then on.
2. If the error persists, replace the DC controller.
80.0X.YY Embedded Jetdirect Error
Description
Embedded HP JetDirect print server critical error.
◦
80.01.80 (event code)
No heartbeat
◦
80.01.81 (event code)
Reclaim time-out
◦
80.01.82 (event code)
Invalid data length
◦
80.01.8B (event code)
Invalid max outstanding packet header field
◦
80.01.8C (event code)
Invalid channel mapping response
◦
80.03.01 (event code)
No PGP buffers
◦
80.03.02 (event code)
Channel table full
◦
80.03.03 (event code)
Producer index not reset
◦
80.03.04 (event code)
Consumer index not reset
◦
80.03.05 (event code)
Queue position size too small
◦
80.03.06 (event code)
Transport overflow
◦
80.03.07 (event code)
No overflow packets
ENWW
Tools for troubleshooting