User Guide
PS461 Tray 4 cassette sensor test
Tray 4 cassette sensor (PW461)
1. Remove the Tray 4 cassette, and then install it to activate the sensor.
Figure 2-20 Test the Tray 4 cassette sensor
2. Check the control-panel display for sensor response.
3. If there is no response, make sure that the sensor-actuator tab on the cassette is not damaged or
missing.
If necessary, replace the optional 500-sheet feeder.
Print/stop test
Use this diagnostic test to isolate the cause of problems such as image-formation defects and jams
within the engine. During this test you can stop the paper anywhere along the product paper path. The
test can be programmed to stop printing internal pages or an external print job when the paper
reaches a certain position. The test can also be programmed to stop from 0 to 60,000 ms. If the timer
is set to a value that is greater than the job-print time, you can recover the product in one of two ways.
1. From the Home screen, scroll to and touch the Administration button.
2. Touch the Troubleshooting button.
3. Touch the Diagnostic Tests button.
4. Scroll to and touch the Print/Stop Test button.
5. Enter a range, and then touch the OK button.
108 Chapter 2 Solve problems ENWW