User Guide
Clearing event log
Description
This message is displayed while the event log is cleared. The product exits the menus when the event
log has been cleared.
Recommended action
No action is necessary.
Clearing paper path
Description
The product is attempting to eject jammed paper.
Recommended action
Check progress at the bottom of the display.
Close inner flap in duplexer
Description
The inner flap in the duplexer is open.
Recommended action
1. Open the lower right door.
2. Close the inner flap in the duplexer.
3. Close the door.
Close rear door
Description
The rear door is open.
Recommended action
1. Close the rear door.
2. If the error persists, verify the J8001 connectors is fully seated on the DC controller PCA.
3. Use the manual sensor test to verify the rear-door sensor functionality. If necessary, replace the
sensor (PS8001).
Close rear door Or touch OK to print to the rear bin
Description
The rear door is open.
240 Chapter 2 Solve problems ENWW