User Guide
First level Second level Value Description
Raw Scan 2-sided
Mechanical
Calibration
Continuous Print from USB
Automatic Calibrations Disabled
Enabled*
Product resets
Restore factory-set defaults
1. From the Home screen on the product control panel, scroll to and touch the Administration button.
2. Open the following menus:
●
General Settings
●
Restore Factory Settings
3. Select one or more categories of settings from the list, and then touch the Reset button.
Restore the service ID
Restore the service ID
If you replace the formatter, the date is lost. Use this menu item to reset the date to the original date that
the product was first used. The date format is YYDDD. Use the following formula to calculate the dates:
1. To calculate YY, subtract 1990 from the calendar year. For instance, if the product was first used
in 2002, calculate YY as follows: 2002 - 1990 = 12. YY = 12.
2. Subtract 1 from 10 (October is the tenth month of the year): 10 - 1 = 9.
●
Multiply 9 by 30: 9 x 30 = 270 or add 17 to 270: 270 + 17 = 287. Thus, DDD = 287.
Convert the service ID to an actual date
You can use the product Service ID number to determine whether the product is still under warranty.
Use the following formula to convert the Service ID into the installation date as follows:
1. Add 1990 to YY to get the actual year that the product was installed.
2. Divide DDD by 30. If there is a remainder, add 1 to the result. This is the month.
3. The remainder from the calculation in step 2 is the date.
326 Chapter 2 Solve problems ENWW