User Guide
59.00.20 Error To continue turn off then on
Description
A motor rotation error has occurred.
Recommended action
Turn the product off and then on.
59.00.30 Error To continue turn off then on
Description
A fuser motor startup error has occurred.
Recommended action
1. Turn the product off and then on.
2. Perform the fuser motor component test in the Troubleshooting menu.
3. Reconnect the connector (J47) on the DC controller PCA.
4. Replace the fuser motor.
59.00.40 Error To continue turn off then on
Description
A fuser motor rotational error has occurred.
Recommended action
1. Turn the product off and then on.
2. Perform the fuser motor component test in the Troubleshooting menu.
3. Reconnect the connector (J47) on the DC controller PCA.
4. Replace the fuser motor.
59.05.50 Error To continue turn off then on
Description
The product experienced a drum motor startup error.
ENWW
Tools for troubleshooting
229