User Guide
Laser scanner failure detection
The DC controller determines a laser scanner failure and notifies the formatter of the error state when
any of the following conditions occurs:
●
BD failure
A specified BD interval is not detected within a specified period during the scanner motor drive.
●
Scanner motor start-up failure
The scanner motor does not reach a specified rotation within a specified period from when the
laser scanner starts driving.
●
Laser failure
A specified laser intensity is not detected.
Laser scanner safety function
The laser scanner has a mechanical shutter. For user and service technician safety, the laser shutter
interrupts optical path of the laser scanner when the cartridge door is open.
ENWW
Laser scanner system
21