HCI motor control
The HCI has two motors in each cassette for the paper-feed and cassette lift-up.
Figure 1-54 HCI motors
HCI cassette lifter motor
HCI cassette pickup motor
Table 1-17 HCI motors
Motor Components driven
M3301 HCI right cassette pickup motor Pickup roller, separation roller and feed roller for the HCI right
cassette
M3302 HCI right cassette lifter motor Lifter for the HCI right cassette
M3303 HCI left cassette lifter motor Lifter for the HCI left cassette
M3304 HCI left cassette pickup motor Pickup roller, separation roller and feed roller for the HCI left
cassette
HCI failure detection
The HCI controller determines a lifter motor failure according to the condition of the related part.
The HCI controller does not determine if the HCI cassette pickup motor has failed; therefore, a jam
occurs when the motor fails.