User Guide

Table 1-18 HCI pickup-and-feed operation components (continued)
Abbreviation Component Signal
PS3103 HCI right cassette media out sensor HCI RIGHT CASSETTE MEDIA OUT signal
PS3201 HCI left cassette media stack surface 2 sensor HCI LEFT CASSETTE MEDIA STACK SURFACE 2
signal
PS3202 HCI left cassette media stack surface 1 sensor HCI LEFT CASSETTE MEDIA STACK SURFACE 1
signal
PS3203 HCI left cassette media out sensor HCI LEFT CASSETTE MEDIA OUT signal
PS3301 HCI media feed sensor HCI MEDIA FEED signal
PS3302 HCI right cassette media feed sensor HCI RIGHT CASSETTE MEDIA FEED signal
PS3303 HCI right cassette media size sensor HCI RIGHT CASSETTE MEDIA SIZE signal
PS3304 HCI left cassette media size sensor HCI LEFT CASSETTE MEDIA SIZE signal
PS3305 HCI left cassette media feed sensor HCI LEFT CASSETTE MEDIA FEED signal
PS3306 HCI long edge feed guide open detection sensor HCI LONG EDGE FEED GUIDE OPEN DETECTION
signal
SW3301 HCI right door open detection switch HCI RIGHT DOOR OPEN DETECTION signal
SW3302 HCI right cassette open detection switch HCI RIGHT CASSETTE OPEN DETECTION signal
SW3303 HCI left cassette open detection switch HCI LEFT CASSETTE OPEN DETECTION signal
HCI cassette media-size detection and cassette-presence detection
The HCI controller detects the size of paper loaded in the cassette by monitoring the HCI cassette
media size sensors. It determines whether A4-R or Letter-R is loaded and notifies the formatter through
the DC controller. It also detects whether the cassette is installed to the 3,500-sheet paper deck by
monitoring the HCI cassette open detection switches and notifies the formatter through the DC
controller.
The cassette media-size detection and the cassette-presence detection are not performed during Sleep
mode.
ENWW
3,500-sheet high-capacity input (HCI) feeder
71