HP ProLiant ML110 G3 Lights-Out 100 Remote Management Processor User Guide

Using Integrated Lights-Out 100 28
3.
Configure the network settings by entering the following: set <network property>=<new
setting>. Configurable valid network properties are:
networkaddress—Specifies the IP address for the NIC. This is the dynamic setting.
oemhp_nonvol_networkaddress—Specifies the IP address stored in non-volatile memory.
oemhp_mask—Specifies the subnet mask for NIC. This is the dynamic setting.
oemhp_nonvol_mask—Specifies the subnet mask stored in non-volatile memory.
oemhp_gateway—Specifies the gateway IP address for the NIC. This is a dynamic setting.
oemhp_nonvol_gateway—Specifies the gateway IP address stored in non-volatile memory.
oemhp_dhcp_enable—Specifies whether DHCP is enabled for the NIC. Boolean values are
accepted
oemhp_nonvol_dhcp_enable—Specifies whether DHCP is enabled for the NIC and address
stored in non-volatile memory.
IPMI Platform Event Filtering configuration pages
Each of the PEF pages enables the configuration of the remote management processor to take selected
actions on event messages that it receives or has internally generated. The actions include operations such
as system power-off, system reset, and triggering the generation of an alert.
To configure a PEF for a particular sensor, click the PEF button on the far right of that sensor on the
Monitoring Sensors page, which opens the IPMI PEF Configuration page for that sensor.
The PEF Configuration page has two sections for the sensors:
Current PEF Entries
Add PEF Entry
The Current PEF Entries section includes:
Sensor Type
Sensor Name
PEF Action
PEF Control