Service manual

Chapter 2 System Information
11
IRQ Settings
The IRQ settings are automatically assigned and don't require user intervention. The HP Netserver uses the
Plug-and-Play feature of the PCI boards to automatically assign resources. Technical Specifications
The specifications listed below vary if you install a mass storage device in your server that has more
stringent environmental limits. Ensure the operating environment for your server is suitable for all of the mass
storage devices being used.
Specifications
Environment
Temperature
Operating 5
° to 35° C (41° to 95° F)
Non-operating -40° to +65° C (-40° to +149° F)
Humidity
Operating 20% to 80% relative humidity, non-condensing
Non-operating 5% to 95% relative humidity, non-condensing
Altitude
Operating -30 to 3,000 m (~ 10,000 ft)
Non-operating -30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum Operating 1007 BTU/hr
Weight and Dimensions
Specification Value
Weight 32 lbs. (14.5 kg.) fully loaded (3 SCSI HDDs, 2 processors, and 4 DIMMs);
excludes keyboard, mouse, and monitor.
Height 1.75 inches (44.5 mm)
Width 16.8 inches (428 mm)
Depth 23 inches (585 mm)