HP ZBook 15 G2 Mobile Workstation Maintenance and Service Guide

a. Disconnect the webcamera/microphone module cable (1) from the webcamera/
microphone module.
b. Detach the webcamera/microphone module (2) from the display enclosure. (The webcamera/
microphone module is attached to the display enclosure with double-sided adhesive.)
c. Remove the webcamera/microphone module.
The webcamera/microphone module is available using spare part number 784208-001. The
microphone module is available using spare part number 735370-001.
22. If it is necessary to replace the display hinges:
a. Remove the four Torx T8M2.5×4.5 screws (1) that secure the display hinges to the display panel.
86 Chapter 6 Removal and replacement procedures for Authorized Service Provider parts