Step 9. Save current configuration. Run:
Step 10. Reboot the switch to run the new image. Run:
4.3.2 Deleting Unused Images
To delete unused images:
Step 1. Enter Config mode. Run:
Step 2. Get a list of the unused images. Run
switch (config) # configuration write
switch (config)#
switch (config) # reload
Configuration has been modified; save first? [yes] yes
Configuration changes saved.
Rebooting...
switch (config)#
After software reboot, the software upgrade will also automatically upgrade the firm-
ware version.
On SX65XX systems with dual management, the software must be upgraded on both
the Master and the Slave units.
In order to upgrade the system on dual management system refer to Section 4.3.1,
“Upgrading MLNX-OS Software,” on page 135.
When performing upgrade from the WebUI, make sure that the image you are trying to
upgrade to is not located already in the system (i.e. fetched from the CLI).
switch >
switch > enable
switch # configure terminal
switch (config) # show images
Images available to be installed:
image-PPC_M460EX-SX_3.1.1224.img
SX-OS_PPC_M460EX SX_3.1.1224 2011-04-28 12:29:48 ppc
Installed images:
Partition 1:
SX-OS_PPC_M460EX 3.1.0000-dev-HA 2011-04-10 12:02:49 ppc