Mellanox MLNX-OS User Manual for SX1018HP Ethernet Managed Blade Switch
Rev 2.10
Mellanox Technologies
198
Mellanox Technologies Confidential
logging monitor
logging monitor <facility> <priority-level>
no logging monitor <facility> <priority-level>
Sets monitor log facility and level to print to the terminal.
The no form of the command disables printing logs of facilities to the terminal.
Syntax Description facility
• mgmt-front
• mgmt-back
• mgmt-core
• events
• sx-sdk
• mlnx-daemons
• iss-modules
priority-level
• none
•emerg
•alert
•crit
•err
• warming
• notice
•info
• debug
Default no logging monitor
Configuration Mode Config
History 3.3.4000
Role admin
Example
switch (config) # logging monitor events notice
switch (config) #
Related Commands
Note