Mellanox MLNX-OS User Manual for SX1018HP Ethernet Managed Blade Switch
Rev 2.10
Mellanox Technologies
218
Mellanox Technologies Confidential
4.7 Event Notifications
MLNX-OS features a variety of supported events. Events are printed in the system log file, and,
optionally, can be sent to the system administrator via email, SNMP trap or directly prompted to
the terminal.
4.7.1 Supported Events
The following table presents the supported events and maps them to their relevant MIB OID.
Table 22 - Supported Event Notifications and MIB Mapping
Event Name Event Description MIB OID Comments
asic-chip-down ASIC (chip) down Mellanox-EFM-MIB:
asicChipDown
Not supported
cpu-util-high CPU utilization has risen
t
oo high
Mellanox-EFM-MIB:
cpuUtilHigh
disk-space-low File system free space has
fall
en too low
Mellanox-EFM-MIB:
diskSpaceLow
health-module-status Health module status
ch
anged
Mellanox-EFM-MIB:
systemHealthStatus
insufficient-fans Insufficient amount of fans
in system
Mellanox-EFM-MIB:
insuf
ficientFans
insufficient-fans-recover Insufficient amount of fans
in system
recovered
Mellanox-EFM-MIB:
insufficientFansRecover
insufficient-power Insufficient power supply Mellanox-EFM-MIB:
insuf
ficientPower
interface-down An interface’s link state
has
changed to DOWN
RFC1213: linkdown
(SNMPv1)
Supported for
Ethernet, InfiniBand
and management
interfaces for 1U
and blade systems
interface-up An interface’s link state
has
changed to UP
RFC1213: linkup
(SNMPv1)
Supported for
Ethernet, InfiniBand
and management
interfaces for 1U
and blade systems.
internal-bus-error
Internal bus (I
2
C) error
Mellanox-EFM-MIB:
int
ernalBusError
liveness-failure A process in the system is
d
etected as hung
Not implemented
low-power Low power supply Mellanox-EFM-MIB:
low
Power
low-power-recover Low power supply recover Mellanox-EFM-MIB:
lowPowerRecover