Mellanox MLNX-OS User Manual for SX1018HP Ethernet Managed Blade Switch
Rev 2.10
Mellanox Technologies
37
Mellanox Technologies Confidential
3.2.4 Ports Menu
The Ports menu displays the port state and enables some configuration attributes of a selected
port. It also enables modification of the port configuration. A graphical display of traffic over
time (last hour or last day) through the port is also available.
Table 17 - Ports Submenus
Submenu Title Description
Ports Manages port attributes, counters, transceiver info and displays a graphical coun-
ters histogram.
Phy Profile Provides the ability to manage phy profiles.
Protocol type Manages the link protocol type
3.2.5 Status Menu
The Status menu makes available the following sub-menus (listed in order of appearance from
top to bottom):
Table 18 - Status Submenus
Submenu Title Description
Summary Displays general information about the switch system and the MLNX-OS image,
including: current date and time, hostname, uptime of system, system memory,
CPU load averages, etc.
Profile and Capabilities Displays general information about the switch system capabilities such as the
enabled profiles (e.g IB/ETH) and
their corresponding values.
Temperature Provides a graphical display of the switch module sensors’ temperature leve
ls
over time (1 hour). It is possible to display either the temperature level of one
module’s sensor or the temperature levels of all the module sensors’ together.
Power Supplies Provides a graphical display of one of the switch’s power supplies voltage level
over time
(1 hour).
Fans Provides a graphical display of fan speeds over time (1 hour). The display is per
fan
unit within a fan module.
CPU Load Provides a graphical display of the management CPU load over time (1 hour).
Memory Provides a graphical display of memory utilization over time (1 day).
Network Provides a graphical display of network usage (transmitted
and received packets)
over time (1 day). It also provides per interface statistics.
Logs Displays the system log messages. It is possible to display either the currently
saved system
log or a continuous system log.
Maintenance Used to perform specific maintenance operations automatically on a predefined
schedul
e.