Step 4. (Optional) Verify in-band management configuration. Run:
Step 5. 618orappropriate
4.2 Software Management
4.2.1 Upgrading MLNX-OS® Software
To upgrade MLNX-OS software on your system, perform the following steps:
Step 1. Change to Config mode.
Step 2. Obtain the previously available image (.img file). You must delete this image in the next step to
make room for fetching the new image.
switch (config) # show interfaces vlan10
Interface vlan10 status:
Comment:
Admin up: yes
Link up: yes
DHCP running: no
IP address: 10.10.10.10
Netmask: 255.255.255.0
IPv6 enabled: no
Speed: N/A
Duplex: N/A
Interface type: ethernet
Interface source: vlan
MTU: 1500
HW address: 00:02:C9:7E:24:E8
RX bytes: 0 TX bytes: 250
RX packets: 0 TX packets: 3
RX mcast packets: 0 TX discards: 0
RX discards: 0 TX errors: 0
RX errors: 0 TX overruns: 0
RX overruns: 0 TX carrier: 0
RX frame: 0 TX collisions: 0
TX queue len: 0
switch (config) #
When upgrading from a software version older than 3.2.0100 to software version
3.3.0000 or higher, the upgrade procedure must be done in two steps. First update the
software to 3.2.0300-100 (for InfiniBand platforms) or 3.2.0506 (for Ethernet plat-
forms), then update to the desired software version.
switch > enable
switch # configure terminal
switch (config) #
switch (config) # show images
Installed images: