Mellanox MLNX-OS®Command Reference Guide for SX1018HP Ethernet Managed Blade Switch
Rev 1.6.2
Mellanox Technologies
248
email notify event
email notify event <event name>
no email notify event <event name>
Enables sending email notifications for the specified event type.
The no form of the command disables sending email notifications for the specified
event type.
Syntax Description event name Example event names would include “process-crash”
and “cpu-util-high”.
Default No events are enabled
Modes/Context Config
History 3.1.0000
Role admin
Example
switch (config) # email notify event process-crash
switch (config) # show email events
Failure events for which emails will be sent:
process-crash: A process in the system has crashed
unexpected-shutdown: Unexpected system shutdown
Informational events for which emails will be sent:
liveness-failure: A process in the system was detected as hung
process-exit: A process in the system unexpectedly exited
cpu-util-ok: CPU utilization has fallen back to normal levels
cpu-util-high: CPU utilization has risen too high
disk-io-ok: Disk I/O per second has fallen back to acceptable levels
...
temperature-too-high: Temperature has risen too high
All events for which autosupport emails will be sent:
process-crash: A process in the system has crashed
liveness-failure: A process in the system was detected as hungswitch
(config) #
switch (config) #
Related Commands show email
Note This does not affect auto-support emails. Auto-support can be disabled overall, but if
it is enabled, all auto-support events are sent as emails.