Mellanox MLNX-OS®Command Reference Guide for SX1018HP Ethernet Managed Blade Switch
Rev 1.6.2
Mellanox Technologies
267
stats sample <sample-id> enable
stats sample <sample-id> enable
no states sample <sample-id> enable
Enables the sample.
The no form of the command disables the sample.
Syntax Description sample-id Possible sample IDs are:
• congested
• cpu_util - CPU utilization: milliseconds of time spent
• disk_device_io - Storage device I/O statistics
• disk_io - Operating system aggregate disk I/O: KB/sec
• eth
• fan - Fan speed
• fs_mnt_bytes - Filesystem usage: bytes
• fs_mnt_inodes - Filesystem usage: inodes
•ib
• interface - Network interface statistics
• intf_util - Network interface utilization: bytes
• memory - System memory utilization: bytes
• paging - Paging activity: page faults
• power - Power supply usage
• power-consumption
• temperature - Modules temperature
Default Enabled
Modes/Context Config
History 3.1.0000
Role admin
Example
switch (config) # stats sample temperature enable
switch (config) #
Related Commands show stats sample