Mellanox MLNX-OS®Command Reference Guide for SX1018HP Ethernet Managed Blade Switch

Rev 1.6.2
Mellanox Technologies
274
2.20 Chassis Management
show stats sample
show stats sample [<sample ID>]
Displays sampling interval for all samples, or the specified one.
Syntax Description sample ID Possible sample IDs are:
congested
cpu_util - CPU utilization: milliseconds of time spent
disk_device_io - Storage device I/O statistics
disk_io - Operating system aggregate disk I/O: KB/sec
eth
fan - Fan speed
fs_mnt_bytes - Filesystem usage: bytes
fs_mnt_inodes - Filesystem usage: inodes
•ib
interface - Network interface statistics
intf_util - Network interface utilization: bytes
memory - System memory utilization: bytes
paging - Paging activity: page faults
power - Power supply usage
power-consumption
temperature - Modules temperature
Default N/A
Modes/Context Config
History 3.1.0000
Role admin
Example
switch (config) # show stats sample fan
Sample "fan" (Fan speed):
Enabled: yes
Sampling interval: 1 minute 11 seconds
switch (config) #
Related Commands N/A
Note
health
health {max-report-len <length> | re-notif-cntr <counter> | report-clear}
Configures health daemon settings.