Mellanox MLNX-OS®Command Reference Guide for SX1018HP Ethernet Managed Blade Switch

Rev 1.6.2
Mellanox Technologies
70
clock timezone
clock timezone [<zone word> [<zone word> [<zone
word>] [<zone word>]]]
Sets the system time zone. The time zone may be specified in one of three ways:
A nearby city whose time zone rules to follow. The system has a large list of cities which
can be displayed by the help and completion system. They are organized hierarchically
because there are too many of them to display in a flat list. A given city may be required to
be specified in two, three, or four words, depending on the city.
An offset from UTC. This will be in the form UTC-offset UTC, UTC-offset UTC+<0-14>,
UTC-offset UTC-<1-12>.
UTC (Universal Time, which is almost identical to GMT), and this is the default time zone
The no form of the command resets time zone to its default (GMT).
Syntax Description zone word The possible forms this could take include: continent,
city, continent, country, city, continent, region, country,
city, ocean, and/or island.
Default GMT
Modes/Context Config
History 3.1.0000
Role admin
Example
switch (config) # clock timezone America North United_States Other
New_York
switch (config) # show clock
Time: 04:21:44
Date: 2012/02/26
Time zone: America North United_States Other New_York
switch (config) #
Related Commands show clock
Note