SX1018HP Ethernet Managed Blade Switch User Guide for HP c-Class BladeSystems
SX1018HP Ethernet Managed Blade Switch HW User Manual Rev 1.0
Mellanox Technologies
13
2 Hardware Installation
This chapter contains the following sections:
• Installing the Mellanox SX1018HP Ethernet Switch
• Installing and removing cables in the Mellanox SX1018HP Ethernet Switch
2.1 Installing the Mellanox SX1018HP Ethernet Switch
2.1.1 Prepare the Interconnect Module Bay in the HP BladeSystem c7000 Enclosure
To prepare the interconnect module bay in the HP BladeSystem c7000 enclosure, follow
these steps:
1. Remove any devices or blanks.
2. To remove the divider, press the divider release button and slide the divider out of the inter-
connect module bay (see Figure 7).
Figure 7: Removing a Divider from the HP BladeSystem c7000 Enclosure Bay
3. Press the divider release button.
4. Slide divider out from the interconnect module bay.
All panels and doors should be in place and securely fastened while the unit is in opera-
tion for proper cooling and for EMI emissions control.