SX1018HP Ethernet Managed Blade Switch User Guide for HP c-Class BladeSystems
SX1018HP Ethernet Managed Blade Switch HW User Manual Rev 1.0
Mellanox Technologies
17
3 Configuring the Switch the First Time
The procedures described in this chapter assume that you have already installed and powered-on
your switch according to the instructions in this document.
Step 1. If you are not already connected to the Onboard Administrator, connect to the Onboard Admin-
istrator of the Chassis using the serial port to your laptop.
For more information see the http://www.hp.com/support/
BladeSystem_Onboard_Administrator_UG_en
Step 2. Connect to the HP Onboard Administrator and run “connect interconnect <slot number 1-7>”.
Step 3. Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term) on
your host PC with the settings described in
Table 5.
Step 4. Login (from a serial terminal program) as admin and use admin as password. This starts the
Mellanox configuration wizard.
Step 5. Go through the Mellanox configuration wizard. Table 6 shows an example of a wizard session.
No remote IP connection is available at this stage.
Table 5 - Serial Terminal Program Configuration
Parameter Setting
Baud Rate 9600
Data bits 8
Stop bits 1
Parity None
Flow Control None
Table 6 - Configuration Wizard Session - DHCP (Sheet 1 of 2)Configuration (Example)
Wizard Session Display Comments
Mellanox configuration wizard
Do you want to use the wizard
for initial configuration? yes
You must perform this configuration the first time you
operate the switch or after resetting the switch. Type ‘y’
and then press <Enter>.
Step 1: Hostname? [switch] If you wish to accept the default hostname, then press
<Enter>. Otherwise, type a different hostname and press
<Enter>.