HP Smart Array Cluster Storage System

Display Messages
HP Smart Array Cluster Storage System User Guide C-11
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
50 REDUNDANCY
FAILED OUT OF
MEMORY
Error While either attempting
to enter redundant mode
or already operating in
redundant mode, one of
the array controllers
failed to allocate required
memory. Redundancy is
disabled at this time.
If the Smart Array Cluster
Storage system is currently
involved in host I/O:
1. Remove the standby
array controller.
2. Wait 10 seconds.
3. Reinsert the controller,
and be sure that it
seats fully in the
chassis.
If this action does not solve
the problem, wait until
downtime is available and
do the following:
1. Power down the Smart
Array Cluster Storage
system.
2. Remove both array
controllers.
3. Reinstall both array
controllers, and be sure
that they seat fully in
the chassis.
If this action does not solve
the problem, contact HP
support.
continued