HP Smart Array Cluster Storage System

Display Messages
C-30 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
123 TOO MANY
VOLUMES
DETECTED
Error The controller detected
more than 32 volumes
(maximum supported) at
power up.
This condition can occur
when the ACU migrates
a set of volumes from
one array controller to a
different array controller
that already contains
configured volumes.
The controller does not
add the migrated
volumes.
1. Remove the migrated
drives.
2. Run ACU.
3. Delete any unneeded
volumes until the
number of existing
volumes plus the
number of volumes
awaiting migration is
equal to or less than 32
volumes.
4. Add the migrated
volumes.
If this action does not solve
the problem, contact HP
support.
124 SPARES
CLEARED
Informational A set of volumes have
been migrated from one
array controller to a
different array controller
that already contains
configured volumes. The
migrated volumes have
spares defined for them
that conflict with the
existing configuration.
The defined spares have
been deleted to allow the
migration to proceed.
Run ACU to reassign spare
drives as needed.
continued