HP Smart Array Cluster Storage System

Display Messages
HP Smart Array Cluster Storage System User Guide C-33
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
204 ARRAY
CONTROLLER
DISABLED
Error The array controller is
disabled because of a
redundancy failure.
1. Remove the failed array
controller.
2. Wait 10 seconds.
3. Reinstall the array
controller, and be sure
that it seats fully.
If this action does not solve
the problem, contact HP
support.
205 ARRAY
CONTROLLER
RESTARTING
Informational The array controller has
completed Controller
Firmware Auto Cloning
and is restarting
automatically.
300 RECOVERY
ROM AUTOFLASH
STARTED
Informational Indicates that the array
controller detected that
the firmware’s backup
recovery ROM image is
invalid and is copying the
current active firmware
image into the backup
recovery ROM.
301 RECOVERY
ROM AUTOFLASH
DONE
Informational Indicates that the array
controller successfully
completed the process of
copying the current
active firmware image
into the backup recovery
ROM.
continued