HP Smart Array Cluster Storage System

Display Messages
C-36 HP Smart Array Cluster Storage System User Guide
COMPAQ CONFIDENTIAL
Writer: Rob Weaver File Name: i-appc Display Messages
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/8/02 3:50 PM
Table C-1: Display Messages continued
Message Type Description Action
309 EMU FLASH
STARTED
Informational Indicates that the I/O
EMU in the Smart Array
Cluster Storage system
is flashing the firmware.
Do not power down the
system until the process is
complete.
The process could take up
to 5 minutes.
If this action does not solve
the problem, contact HP
support.
310 EMU FLASH
DONE
Informational Indicates that the I/O
EMU in a Smart Array
Cluster Storage system
completed the firmware
flash process.
Power down the system.
311 EMU FLASH
FAILED
Error Indicates that the I/O
EMU in a Smart Array
Cluster Storage system
has failed the firmware
flash process.
Attempt the flash process
again.
If this action does not solve
the problem, contact HP
support.
400 STORAGE BOX
#<n> FAN OK
Informational The specified storage
enclosure indicates that
one of its previously
failed or degraded fans is
now operating normally.
401 STORAGE BOX
#<n> FAN FAILED
Error The specified storage
enclosure indicates that
one of its fans has failed.
The storage enclosure
and any devices in it may
now be susceptible to
overheating if corrective
action is not taken.
1. Be sure that all Smart
Array Cluster Storage
system fans are
operating.
2. Replace any failed
fans.
If this action does not solve
the problem, contact HP
support.
continued