HP Smart Array Cluster Storage System

Component Identification
HP Smart Array Cluster Storage System User Guide 1-17
HP CONFIDENTIAL
Writer: Rob Weaver File Name: b-ch1 Component Identification
Codename: Aurora Part Number: 240333-003 Last Saved On: 11/6/02 1:03 PM
Hot-Plug SCSI Hard Drive LED Combinations
Table 1-12: Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
Online
LED
Fault
LED
Status
On Flashing Off
Do not remove the drive. Removing a drive during this
process can cause data loss in non-fault-tolerant
configurations
The drive is a replacement drive and is being rebuilt or
If all online LEDs in a drive array are flashing, an
expansion is occurring.
Off Off On OK to replace the drive online.
The drive has failed and has been placed offline.
Off, on, or
flashing
On Off
Do not remove the drive. Removing a drive during this
process can cause data loss in non-fault-tolerant
configurations.
The drive is online and configured as part of an array.
Off, on, or
flashing
On or Off Flashing A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.