Command Reference Guide

Remote Monitoring Commands
CLI Command Reference
September 2014 Page 266
HP Moonshot Switch Module CLI Command Reference
Example: The following shows example CLI display output for the command.
(Routing) #show rmon hcalarms
Index OID Owner
----------------------------------------------
1 alarmInterval.1 MibBrowser
2 alarmInterval.1 MibBrowser
High Capacity Alarm Rising-
Threshold Absolute Value Low
The lower 32 bits of the absolute value for threshold for the sampled statistic.
The range is 0 to 4294967295. The default is 1.
High Capacity Alarm Rising-
Threshold Absolute Value High
The upper 32 bits of the absolute value for threshold for the sampled statistic.
The range is 0 to 4294967295. The default is 0.
High Capacity Alarm Rising-
Threshold Value Status
This object indicates the sign of the data for the rising threshold, as defined by
the objects hcAlarmRisingThresAbsValueLow and
hcAlarmRisingThresAbsValueHigh. Possible values are valueNotAvailable,
valuePositive, or valueNegative. The default is valuePositive.
High Capacity Alarm Falling-
Threshold Absolute Value Low
The lower 32 bits of the absolute value for threshold for the sampled statistic.
The range is 0 to 4294967295. The default is 1.
High Capacity Alarm Falling-
Threshold Absolute Value High
The upper 32 bits of the absolute value for threshold for the sampled statistic.
The range is 0 to 4294967295. The default is 0.
High Capacity Alarm Falling-
Threshold Value Status
This object indicates the sign of the data for the falling threshold, as defined
by the objects hcAlarmFallingThresAbsValueLow and
hcAlarmFallingThresAbsValueHigh. Possible values are valueNotAvailable,
valuePositive, or valueNegative. The default is valuePositive.
High Capacity Alarm Rising
Event Index
The index of the eventEntry that is used when a rising threshold is crossed.
The range is 1 to 65535. The default is 1.
High Capacity Alarm Falling
Event Index
The index of the eventEntry that is used when a falling threshold is crossed.
The range is 1 to 65535. The default is 2.
High Capacity Alarm Failed
Attempts
The number of times the associated hcAlarmVariable instance was polled on
behalf of the hcAlarmEntry (while in the active state) and the value was not
available. This object is a 32-bit counter value that is read-only.
High Capacity Alarm Owner The owner string associated with the alarm entry. The default is
monitorHCAlarm.
High Capacity Alarm Storage
Type
The type of non-volatile storage configured for this entry. This object is read-
only. The default is volatile.
Parameter Description