lldp timers
Use this command to set the timing parameters for local data transmission on ports enabled for LLDP. The
interval-seconds determines the number of seconds to wait between transmitting local data LLDPDUs. The
range is 1-32768 seconds. The
hold-value is the multiplier on the transmit interval that sets the TTL in local
data LLDPDUs. The multiplier range is 2-10. The
reinit-seconds is the delay before re-initialization, and the
range is 1-0 seconds.
no lldp timers
Use this command to return any or all timing parameters for local data transmission on ports enabled for LLDP
to the default values.
lldp transmit-tlv
Use this command to specify which optional type length values (TLVs) in the 802.1AB basic management set
are transmitted in the LLDPDUs from an interface or range of interfaces. Use
sys-name to transmit the system
name TLV. To configure the system name, see “snmp-server” on page 100. Use
sys-desc to transmit the system
description TLV. Use
sys-cap to transmit the system capabilities TLV. Use port-desc to transmit the port
description TLV. To configure the port description, see Seedescription” on page 270.
no lldp transmit-tlv
Use this command to remove an optional TLV from the LLDPDUs. Use the command without parameters to
remove all optional TLVs from the LLDPDU.
Default interval—30 seconds
•hold4
reinit—2 seconds
Format
lldp timers [interval interval-seconds] [hold hold-value] [reinit reinit-seconds]
Mode Global Config
Format
no lldp timers [interval] [hold] [reinit]
Mode Global Config
Default no optional TLVs are included
Format
lldp transmit-tlv [sys-desc] [sys-name] [sys-cap] [port-desc]
Mode Interface Config
Format
no lldp transmit-tlv [sys-desc] [sys-name] [sys-cap] [port-desc]