show udld
This command displays the global settings of UDLD.
If no optional parameters are entered, the information in the following table displays.
Example: The following shows example CLI display output for the command after the feature was enabled
and non-default interval values were configured.
(Routing) #show udld
Admin Mode..................................... Enabled
Message Interval............................... 13
Timeout Interval............................... 31
Format
show udld
Mode • User EXEC
•Privileged EXEC
Parameter Description
Admin Mode The global administrative mode of UDLD.
Message Interval The time period (in seconds) between the transmission of UDLD probe packets.
Timeout Interval The time period (in seconds) before making a decision that the link is unidirectional.