Switching Silicon USL: failed to sync stg table on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Switching Silicon USL: A Trunk doesn't exist in USL Attempting to modify a Trunk that doesn’t
exist.
Switching Silicon USL: A Trunk being created by bcmx already
existed in USL
Possible synchronization issue between the
application, hardware, and sync layer.
Switching Silicon USL: A Trunk being destroyed doesn't exist in
USL
Possible synchronization issue between the
application, hardware, and sync layer.
Switching Silicon USL: A Trunk being set doesn't exist in USL Possible synchronization issue between the
application, hardware, and sync layer.
Switching Silicon USL: failed to sync trunk table on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Switching Silicon USL: Mcast entry not found on a join Possible synchronization issue between the
application, hardware, and sync layer.
Switching Silicon USL: Mcast entry not found on a leave Possible synchronization issue between the
application, hardware, and sync layer.
Switching Silicon USL: failed to sync dvlan data on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Switching Silicon USL: failed to sync policy table on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Switching Silicon USL: failed to sync VLAN table on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Switching Silicon Invalid LAG id x Possible synchronization issue between the
BCM driver and HAPI.
Switching Silicon Invalid uport calculated from the BCM uport
bcmx_l2_addr->lport = x
Uport not valid from BCM driver.
Switching Silicon Invalid USP calculated from the BCM
uport\nbcmx_l2_addr->lport = x
USP not able to be calculated from the learn
event for BCM driver.
Switching Silicon Unable to insert route R/P Route R with prefix P could not be inserted in
the hardware route table. A retry will be
issued.
Switching Silicon Unable to Insert host H Host H could not be inserted in hardware
host table. A retry will be issued.
Switching Silicon USL: failed to sync L3 Intf table on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Switching Silicon USL: failed to sync L3 Host table on unit = x Could not synchronize unit x due to a
transport failure or API issue on remote unit.
A synchronization retry will be issued.
Table 59: Switching Silicon Error Messages (Cont.)
Component Message Cause