User's Manual

The Thermal table displays the following information for the selected cartridge:
Sensor—The ID of the temperature sensor, which also gives an indication of the sensor’s
location.
Status—The temperature status of the cartridge. Depending on the server cartridge
configuration, some sensors show a status of Not installed.
Current Reading—The temperature recorded by the listed temperature sensor. If a temperature
sensor is not installed, the Current Reading column shows the value N/A.
Thresholds—The temperature thresholds for the warning for overheating conditions. The two
threshold values are Caution and Critical. If a temperature sensor is not installed, the Thresholds
column shows the value N/A.
Caution—The cartridge is designed to maintain a temperature below the caution threshold
while operating. If a failure prevents the cartridge from maintaining this temperature, the
chassis increases the fan speed and initiates a graceful operating system shutdown. This
ensures both data integrity and system safety.
Critical—If temperatures are uncontrollable or rise quickly, the critical temperature threshold
prevents system failure by physically shutting down the cartridge before the high
temperature causes an electronic component failure.
Temperature Meter—A graphical representation of the current temperature reading and
whether that reading has reached the Caution or Critical thresholds. The left edge of the
column represents a temperature of 0°C, the grey bar represents the Caution threshold, and
the right edge of the column represents the Critical threshold. If a temperature sensor is not
installed, is missing, or is not reporting a temperature reading, an empty graph is displayed.
Viewing ProLiant server cartridge node information
The Moonshot web interface Nodes page displays information about the HP ProLiant server
cartridges installed in the chassis.
Viewing overview information 21