Configuring and Managing Host-Based X.25 Links - Edition 5 (36939-90054)

Chapter 3 75
Configuring DTCs Step-by-Step
Modify the Network Management Configuration File
4. Move the cursor to the first Address field under Enter remote
X.25 addresses and security. Enter the X.25 address of a
system that will be able to establish a system-to-system connection
with the HP 3000 Series 900 you are configuring.
5. Move the cursor to the Sec. field next to the address you just
entered. Enter the security level for connections between the remote
X.25 address and the system you are configuring. Possible values are
IN (accept calls from the address), OU (send calls to the address), and
IO (accept calls from and send calls to the address).
6. Repeat steps 4 and 5 for each remote system that will be able to
establish a system-to-system connection with the HP 3000
Series 900 you are configuring. If you need to enter more than eight
remote system addresses, press the
[Save Data] key to save the data
on this screen, then use the
[Next Page] key to move to a new data
entry screen to configure additional addresses.
7. When you have entered all remote X.25 addresses and associated
security, press the
[Save Data] key to save the configuration.
8. Press the
[Go To PAD] key to move to the DTC X.25 Card
Configuration — Nailed PAD Connections screen.
Fields
This screen lets you configure X.25 system-to-system local user
group (LUG) information for the DTC/X.25 Network Access card
being configured.
DTC name Display only.
Card number Display only.
X.25 link
name The name of the link that will be used by the system
being configured for X.25 system-to-system
connections. Must be the same as the link name
entered during NS configuration of X.25 iX System
Access using the NS subbranch of NMMGR. The
link name can be up to eight alphanumeric
characters, beginning with a letter.
Maximum number
of Switched
Virtual
Circuits The number of switched virtual circuits (SVCs) that
will be allowed through this DTC/X.25 Network
Access card. Up to 32 SVCs are allowed for cards
mounted in a DTC 16, up to 256 SVCs are allowed
for cards mounted in a DTC 48 and up to 156 SVCs